CHZIRI ZVF510 Series Frequency Inverter Application Ambient
ZVF510 Series can be used for pump and fan . but can not work for the application need big torque at low frequency .
Industrial Manufacturing
1.Lightweight conveyor belt systems
Conveyor belts for light materials (e.g. cartons, plastic parts, textiles) that require speed regulation but have a low load moment.
2.Packaging machines
Speed asynchronous control of sealing machines, labelling machines and filling machines with light loads and mainly constant speed operation.
3.Small mixing equipment
Mixing of low-viscosity liquids or powders in the food and chemical industries without the need for high starting torques。
4.Textile machinery
The winding speed control of spinning machines and winding machines relies on smooth speed regulation rather than high torque
5.Automated sorting system
The conveyor module of the logistics sorting line is light and requires precise start-stop control
6.Material Handling Robots
The drive motor of the AGV (Automated Guided Vehicle) regulates the speed, and the load is light and the operation is stable.
7.Automatic doors and lifting platforms
Smooth start-stop control, such as garage doors, lightweight lifting tables, with low torque requirements
8.Commercial and public facilities
Commercial cleaning equipment
Brush motors for floor scrubbers and glass cleaners, light load and variable speed required.
9.Central air-conditioning auxiliary system
In addition to fans, e.g. water circulation pumps (low flow service) or damper control.
10.laboratory equipment
The speed adjustment of centrifuges and oscillators requires light loads and precise control
Other light-load scenarios
11.Printing Machinery Auxiliary Unit
The auxiliary motor of the paper feeder and laminating machine needs to be adjusted in speed but the load is low.
12.Food processing equipment
The transmission system of the slicer and the packaging and sealing machine runs at a constant speed under light load.For example: braker machine.
13.Recreational facilities
Rotate the motor control of small equipment in booths and playgrounds to avoid high torque requirements
14.Ventilation system auxiliary equipment
Such as smoke exhaust valves, air volume adjustment devices (non-main fans).
Note:
Precautions
In the above scenarios, it is necessary to ensure that the load characteristics of the motor are variable torque or constant power, and avoid long-term operation in low frequency bands (such as < 10Hz) to prevent overheating or insufficient torque.
Before specific application, it is necessary to check the rated parameters of the inverter and the equipment requirements, and install heat dissipation or protection devices if necessary.