Solution

VFD control panel for Car Park

Publish Time: Author: Site Editor Visit: 3858

1.CUSTOMER REQUIREMENT:
we need both forward and reverse drive.

1.CHZIRI SOLUTION:
Kindly set inverter parameters F0.10 to do it.

F0.10 Running direction selection 0: Forward
(the default running direction)
1: Reverse
2: Forbid reverse
1 0 ×

 

2.CUSTOMER REQUIREMENT:

May be emergency stop on panel.The stop button shall give soft stop andthe emergency stop button should give sudden stop.

2.CHZIRI SOLUTION:

Sure, we can plus the button on panel.

3.CUSTOMER REQUIREMENT:

may be a potentiometer button to adjust speed

3.CHZIRI SOLUTION:

You can use our keypad or potentiometer to adjust the speed.kindly check wiring again.

4.CUSTOMER REQUIREMENT:

we will put on the very special things onto the cabinet by ourselves, since that canchange from project to project. lf you put on a long empty DIN rail in for instancebottom of cabinet and a terminal for connections as specified, we can very easycustomize the cabinets to the projects.For instance put on remote relays andtimers.And we assume it for you will be a very standard cabinet to make?

4.CHZIRI SOLUTION:

Sure, we can do it. Please post the size of din rail for us reference..lt is standard 35 mm DlN rail. Can be as long as width of the cabinet.

5.CUSTOMER REQUIREMENT:

What about lP classes for cabinets and pricing? Cabinet should beCE-marked; do you have CE-documentation?

5.CHZIRI SOLUTION:

CHZIRI VFD are approved by CE.
other Accessories is are CHZIRl brand.please visit their web to check CE.

GET A QUOTE

Get in Touch
×
Online Feedback

Contact Us

Contact Us
No.62-70 Daqiao Road ,dongfeng Village , liushi , Yueqing , wenzhou.Zhejiang Province.china.
Contact Us
+86-577-27863300
Contact Us
+86-1350667 4830
Contact Us
chziri@chziri.com