Product Profile
CHZIRI output AC reactor is mainly used for the smoothing filtering. By reducing the transient voltage dv/dt, it extends the service-life of the electrical machine. This equipment is also applied to reduce the noise of the electrical machine, the eddy-current loss and the leak current caused by the output of the higher harmonic. Moreover, it is also employed to protect the power switching components inside the inverter.
Main Features
Based on different operating frequency, clients can reasonably choose the magnetic materials (such as silicon steel sheet, ferrite, amorphous iron core and magnetic powder core) as the raw material of this product.
The excellent performance of this equipment is due to the foil winding structure, low DC resistance, strong resistance to electromagnetic force and good overload ability in short time. F and above class composite insulating materials are used to ensure the reliable performance of the output AC reactor under harsh working conditions; The advantages of the design includes low magnetic flux density, high linearity and good overload capacity. Moreover, the cooperation of the design and the vacuum pressure impregnation process ensures the low noise of the product.
Solution for Inverter output Terminal
Technical Data:
1.Rated operating Voltage: φ3/380V/50Hz
2.Rated operating current: 5A to 1600A
3.Operating environment temperature:40℃
4.Dielectric strength: Core-wingding 3000VAC/50Hz/5mA/10S
No flashover breakdown(factory test)
5.Insulation Resistance>1000VDC, Insulation resistance value >100MΩ.
6.Noise of the reactor is less than 80dB ( Tested at the point with a horizontal distance of 1 meter away from the reactor).
7.Level of protection:IP00
8.Insulation class: Above F
9.Executive standard of product:GB19212.1-2008,GB19212.21-2007.GB1094.6-2011.
Benefits:
◆ Decrease the noise of motor and the losses of eddy current
◆ Decrease the leakage current caused by high order harmonic
◆ Filter harmonic fluently and reduce transient voltage dv/dt to lengthen the lifetime of motor
◆ Protect the power switch components of inverter
Outline& Mounting Dimension (Unit:mm)
380V output AC reactor selection model
Reactor Type | NO. | Power(kW) | Rated Current | Inductance | Voltage Drop | Insulation Class | Material | Weight (Kg) | Dimension(±0.5mm) | ||
D*H*W | D1*W1 | a*b | |||||||||
OCL-0005-EISC-E1M4C | A | 1.5 | 5A | 1.4mH | 1% | F | Cu | 2.4 | 110*130*84 | 91*65 | 6*11 |
OCL-0007-EISC-E1M0C | 2.2 | 7A | 1mH | 1% | F | Cu | 2.4 | 110*130*84 | 91*65 | 6*11 | |
OCL-0010-EISC-EM70C | 3.7 | 10A | 0.7mH | 1% | F | Cu | 2.4 | 110*130*84 | 91*65 | 6*11 | |
OCL-0015-EISC-EM47C | 5.5 | 15A | 0.47mH | 1% | F | Cu | 3 | 155*140*84 | 95*61 | 6*15 | |
OCL-0020-EISC-EM35C | 7.5 | 20A | 0.35mH | 1% | F | Cu | 3.8 | 155*140*84 | 95*61 | 6*15 | |
OCL-0030-EISCL-EM23C | B | 11 | 30A | 0.23mH | 1% | F | Cu | 4.6 | 200*130*116 | 120*72 | 8.5*20 |
OCL-0040-EISCL-EM18C | 15 | 40A | 0.18mH | 1% | F | Cu | 4.8 | 200*130*116 | 120*72 | 8.5*20 | |
OCL-0050-EISCL-EM14C | 18.5 | 50A | 0.14mH | 1% | F | Cu | 5 | 200*130*116 | 120*72 | 8.5*20 | |
OCL-0060-EISCL-EM12C | 22 | 60A | 0.12mH | 1% | F | Cu | 5.1 | 200*130*116 | 120*72 | 8.5*20 | |
OCL-0080-EISC-E87UC | 30 | 80A | 0.09mH | 1% | F | Cu | 6 | 195*165*130 | 120*72 | 8.5*20 | |
OCL-0090-EISC-E78UC | 37 | 90A | 0.08mH | 1% | F | Cu | 6 | 195*165*130 | 120*72 | 8.5*20 | |
OCL-0120-EISC-E58UC | 45 | 120A | 0.06mH | 1% | F | Cu | 9 | 195*165*165 | 150*88 | 8*15 | |
OCL-0150-EISH-E47UC | C | 55 | 150A | 0.05mH | 1% | F | AL | 10 | 195*210*155 | 120*92 | 8.5*20 |
OCL-0200-EISH-E35UC | 75 | 200A | 0.04mH | 1% | F | AL | 12 | 195*210*165 | 120*102 | 8.5*20 | |
OCL-0250-EISH-E28UC | 110 | 250A | 0.03mH | 1% | F | AL | 12 | 195*210*165 | 120*102 | 8.5*20 | |
OCL-0290-EISH-E24UC | 132 | 290A | 0.02mH | 1% | F | AL | 20 | 255*240*175 | 182*91 | 11*18 | |
OCL-0330-EISH-E21UC | 160 | 330A | 0.02mH | 1% | F | AL | 20 | 255*240*175 | 182*91 | 11*18 | |
OCL-0390-EISH-E18UC | 185 | 390A | 0.02mH | 1% | F | AL | 20 | 255*245*175 | 182*91 | 11*18 | |
OCL-0490-EISH-E14UC | 220 | 490A | 0.01mH | 1% | F | AL | 28 | 300*295*190 | 214*95 | 11*18 | |
OCL-0530-EISH-E13UC | 250 | 530A | 0.01mH | 1% | F | AL | 29 | 300*295*190 | 214*95 | 11*18 | |
OCL-0600-EISH-E12UC | 280 | 600A | 0.01mH | 1% | F | AL | 33 | 300*295*210 | 214*110 | 11*18 | |
OCL-0660-EISH-E11UC | 300 | 660A | 0.01mH | 1% | F | AL | 38 | 300*315*210 | 214*110 | 11*18 | |
OCL-0800-EISH-E8U7C | 380 | 800A | 0.01mH | 1% | F | AL | 40 | 325*350*215 | 243*112 | 12*20 | |
OCL-1000-EISH-E7U0C | 450 | 1000A | 0.01mH | 1% | F | AL | 40 | 325*350*215 | 243*112 | 12*20 | |
OCL-1200-EISH-E5U8C | 550 | 1200A | 0.01mH | 1% | F | AL | 56 | 325*395*235 | 243*132 | 12*20 | |
OCL-1600-EISH-E4U3 | 630 | 1600A | 0.01mH | 1% | F | AL | 92 | 395*435*325 | 275*175 | 12*20 |
Note:Parameters are for reference only. If you have any questions, contact our sales department please. Information about the parameters is subject to change without notice.
Wiring Diagram for Inverter System
Related Products
News Center
> Common faults and repair methods of frequency converters, it is recommended to collect them!
Then follow the editor's steps to solve related problems such as the frequency converter failing to start normally and unstable output and how to solve them.
> What is a pump Inverter?
What is a pump Inverter? Generally speaking, it is: AC-DC-AC (or rectification first-then inverter). The pump Inverter that undergoes this process is also called AC-...
> Frequency Inverter manufacturer talks about the differences between servo drive system and inverter system
The frequency inverter manufacturer will introduce to you the differences between servo drive systems and inverter systems, including control objects, control accura...
> Characteristics and application fields of frequency converters
Characteristics of frequency converter1. Adjustable speed: The frequency converter can control the motor output frequency and voltage to realize the motor speed regu...